Solar Panels: A New Addition to Today’s Fire Service Enemy

In a 24 hour period the sun produces enough energy to supply our planet for over four years. That’s 1,460 days of solar energy the planet received in just 24 hours. Solar energy is everywhere and the advancements in it are growing and for many reasons. It's renewable, pollution free and cuts costs of other energy sources. What's this mean for firefighters? Well it means a lot. Solar panels are popping up all over buildings and on plots of land like never before. We're noticing this by a simple placard found on the commercial structures that are now using solar energy with the letters "PV" on it. 

 “PV" which stands for photovoltaic is the method of converting solar energy into direct current electricity (DC) using semiconducting materials that exhibit the "photovoltaic effect". The "P" which stands for photo (light) and the "V" which stands for voltaic (electricity), this of which it bears its name. The PV effect is the creation of voltage or electric current in a material when exposed to light. 

In today's society, solar panels are everywhere just like truss construction is everywhere. Thus creating a need for firefighters to be aware of the dangers and understand how to attack fires with PV systems. 

For firefighters to be safe and operate efficiently on the fireground, there are a few critical steps we must take to ensure the solar panels are accounted for and in check. Do not begin fire suppression until these first 2 steps have been completed.

  • 360 Size-up: This is a no-brainer. By performing a 360 size-up upon arrival, firefighters are able to possibly locate the panels or the energy storage system (ESS) if the panels are on the roof or an area without access to at the time. Most of the time depending on jurisdictional building codes, the ESS panels are located on the exterior of the structure normally near the utilities, the garage or the basement, should the structure have one.

  • Treat this as an electrical fire and turn off the systems starting with the utility grid. The main breaker box will activate the backup battery and run the risk of electrical shock to interior firefighters in the structure. If the battery is located in a confined space in the structure and exposed to heat above 150 degrees Fahrenheit, it is imperative that ventilation of that space begins.

Once the size-up has taken place with the panels and/or ESS located along with fire suppression taking place, ventilations needs to begin. However, firefighters and command need to understand that if the panels are located on the roof and are burning, there is a potential for collapse based on the volume of fire around the panels and on the roof. 

 When performing ventilation, especially vertical ventilation, firefighters must recognize that electricity is being produced by the panels 24 hours a day. 

  • Once these steps have taken place, fire suppression can now continue. As a safety precaution, firefighters should try and extinguish the fire at a minimum of 20 feet away when using a straight stream or a minimum of 5 feet when using a fog pattern.

  • After the fire has been knocked, overhaul can begin - carefully.

Panel safety

Firefighters should be careful not to touch any of the panels in case of any damage done to them during the fire. Instead, firefighters should cover the panels with canvas tarps, especially at night due to no sunlight exposure to them. The reason panels should be covered during night operations is due to the wires running through the conduit to the charge controller or inverter which continues providing the panels power. 

Battery safety

If the battery was the source of the fire, continual water flow to the extinguished battery is important to keep the battery cool and from the possibility of obtaining a chemical reaction causing a thermal runaway. Should a thermal runaway occur, the temperature inside the battery will reach the point that causes a chemical reaction inside the battery. This reaction produces more heat and drives the temperature of the battery higher, causing further chemical reactions and more heat. In thermal runaway, the battery cell temperature will rise in milliseconds and release suddenly. The chain reaction will reach temperatures of around 752 degrees Fahrenheit and produce gassing of the battery along with fire. 

Burns tests have shown that lithium-ion batteries can produce these chemical reactions 72 hours after extinguishment. 

 As technology changes, firefighters need to be educated and trained on all of the new advancements in the market today. By doing so, firefighters can continue to develop a proactive approach to new technology when responding to incidents. Solar panels may not be completely new to us but the growth of them in residential and commercial structures has rapidly increased over the years. Today, it is nearly impossible to not catch a glimpse of solar panels on almost every street across the country. Stay diligent to the advancements in the world and continue to keep training and getting after it.

 Until next time; work hard, stay safe & live inspired.

 

Fire Fact

According to studies, wood burns at 1,880 degrees Fahrenheit which is one degree hotter than gasoline which burns at 1,879 degrees Fahrenheit yet is much less than methanol also known as “wood alcohol” which burns at 2,190 degrees Fahrenheit; 310 degrees hotter than wood but in a normal atmosphere most materials will burn near the same temperature. (Source: NFPA 921, 2014 ed. Table 5.6.5.1.)

In a controlled setting this will stand true since burn times for each of these are vastly different as well as the heat release rate that is being produce by these as well. Temperatures are good to know but also knowing that the more the products of combustion in the room (their respective temperatures will still be produced) the greater the HRR and the greater fire flow needed.

That’s your fire tip of the week! For more on HRR and fire flow check out our article "Importance of Fire Flow in Today's Fire Service" on why an increased fire flow plays a tremendous part in cooling the products of combustion in today’s rapidly changing society.

Understand a Backdraft

In today’s society firefighters are responding to fires during the later stage of the fully developed stage or at beginning of the decaying stage of fire. This is to no fault of our own, in which multiple factors go into this such as time of day, traffic, faulty fire alarms systems or lack thereof, etc., but understanding the risk of responding to fires as this stage and the vital role we play by knowing fire behavior and knowing the effects of what happens at each stage of fire growth. In this stage, we as firefighters are at an inherent risk of responding to confined fires deprived of oxygen and without proper ventilation and coordination, we are adding to the problem rather than making it better. One of the biggest risk we run into is called a backdraft. A backdraft, also known as a smoke explosion NFPA 921: Guide for Fire & Explosion Investigations, 2011 Edition as, “A deflagration resulting from the sudden introduction of air into a confined space containing oxygen-deficient products of incomplete combustion.” 

So let’s talk now about the science of a backdraft. In decaying stage burning is incomplete because of the lack of oxygen feeding the fire, causing the fire to smolder or burn out. Nonetheless, the heat released from the fully developed state still remains and all flammable products of combustion are waiting for an introduction to oxygen so they can instantaneously combust in the room. We as trained firefighters can prevent this act from happening through proper ventilation. By doing so properly and in a timely manner, the upper areas in the room will be cleared from smoke and unburned gases which is done at the highest point possible. Coincidentally, if this is improperly done, the same unburned gases and other products of combustion are now at a higher risk to instantaneously combust once oxygen is introduced to the room causing a devastating effect on the structure and those in and around it. It is to be known that it only takes 25% of the space in a room or fire area to cause a backdraft to occur. 
With this being said there are certain warning signs that can be seen to indicate if a backdraft appears emanate:

• Black smoke becoming dense, greyish yellow

• Confinement and excessive heat

• Little or no visible flame

• Smoke leaving the building in puffs and being drawn back in

• Smoke stained and/or rattling windows

• Muffled sounds

• Sudden, rapid movement of air and smoke inward when an opening is made
Now that we have discussed the science of a backdraft, let us now discuss how we can safely manage this type of situation.

Ventilation

Vertical ventilation is possibly the best and most effective method of venting a structure showing signs of a backdraft. This will allow for the superheated gases to escape without introducing an excessive amount of oxygen into the structure. Should an explosion still occur during vertical vent, the force will be directed up and away from the vent crew that created the opening (roof cuts, skylight pops, etc.). Should vertical ventilation not be possible for us, horizontal ventilation is a consideration. This could be done using pike poles 6 feet or greater and positioning yourself near the corner of the building and moving all companies out of the “hot zone” or collapse zone. 

Quenching

Another method would be to quench the gases. This is done before we enter the room where the superheated gases were present. A few short blasts of water to the ceiling (also known as penciling) will provide enough cooling to stop an explosion from occurring. By doing this, we are controlling the heat release rate (HHR) and if we can control the heat release rate we can control the fire. 

Flanking

If vertical vent and quenching not be an option, we could consider flanking the fire. To flank the fire, we should position engine company crews at the sides of the doorway and cool the room (compartment) with their hose streams. When doing this, make sure to not cross hose streams and take note of the windows in the room, if possible. A psi pressure of a mere 0.5 will blow windows out.  

Let’s all take this and answer these questions next time we are working on the fire ground.

What do you see upon arrival as the initial Incident Commander or first due Engine Company? 

What significance do these observations tell us about the fire conditions?

What's is the smoke telling us? 

What would be your actions?

Until next time; work hard, stay safe and live inspired.  

About the Author

NICHOLAS J. HIGGINS is a firefighter with 14 years of service all within departments in Piscataway, NJ. Nick has held the ranks of Lieutenant and Captain as well as being a township elected District Fire Commissioner for 1 term (3 years) in Piscataway, NJ. He is also a NJ State certified level 2 fire instructor. He holds a B.S. in Accounting from Kean University working in Corporate Taxation and is the founder/contributor of the Firehouse Tribune website.

The Halligan & its Mechanical Advantages for Forcible Entry

The most used and go to tool in the fire service as we all know is the Halligan. The Halligan as we know is used for “everything” from forcing a door to searching a room, making purchase points in vehicle extrication to wall breaches and clearing windows for ventilation or a possible egress. You name it and a Halligan bar will probably be a tool of choice for any job on the fire ground, if not the tool of choice. Every apparatus has one or more on them for a reason, so it’s best we know not only what it’s used for but also know the bar.

Being able to use a Halligan for multiple purposes on the fire ground is wonderful but knowing the dimensions of the Halligan can offer firefighters more of an advantage when using the tool especially during forcible entry.  

But first let’s start with the bar’s history.

The Halligan was invented by Deputy Chief Hugh A. Halligan of the FDNY in the 1940s. Hugh Halligan was first appointed chief of the FDNY on June 16, 1916. Prior to the Halligan, the tools of choice or its predecessors as we could call it were the Claw tool and the Kelly tool. The Claw tool was considered one of the FDNY’s first forcible entry tools. The downside to this tool was its weight and the off-centered striking surface that made it dangerous for the firefighter holding the tool as it was being driven into a door.

The next tool was choice was the Kelly tool which was developed by the then captain of Ladder Company 163, John Kelly. Unlike the Claw tool, the Kelly tools striking surface was inline with the bar and had a 90 degree flat surface (adze end). Similarly to Claw tool, the Kelly tool was also welded and still heavy and due to both tools specific advantages, both were to be used during fire ground operations.

This is where Chief Halligan came in and wanted to develop a tool that could be held in one hand, wouldn’t break or crack and would not fatigue a firefighter while using it. This was the birth of the Halligan bar. The bar was made of cross-drop forged from one piece of No. 4140 high carbon content steel. As soon as the tool was available on the market it was a huge success that the Boston Fire Department was one of the first departments to place a Halligan bar on every ladder company in the department.

Today most of us use the modern take on the Halligan or the Pro Bar as it is called, which is the one tool that has stayed most true to original specs of the Halligan bar. It is fabricated from one piece of drop forged steel and measures 30 inches in length. The forks have a tapered V shape of space between them along with a gradual curve for leverage when prying. The adze end and pick also have a gradual curve for more of an advantage as well.

The dimensions of the Halligan bar

A standard Halligan is 30 inches in overall length. It consists of an adze end, a pick and a fork (or claw). The fork is 6 inches in length and the crotch of the fork is 5 inches – this is key for conventional forcible entry. The adze end is also 6 inches in length and 2 inches wide. The pick is 6 inches in length and the adze/pick triangle is 5 inches tall.  

Now that we know the dimensions of the Halligan bar, how will this help us in forcible entry?

Using the Adze end

More often than not when dealing with outward swinging doors, we will look to gap, crush or tunnel the door between the door (above the lock) and the jamb using the adze end of the Halligan in doing so and moving the tool up or down offering a 15:1 mechanical advantage with a maximum spread of 2 inches (width of the adze). The 15:1 MA is from the 30 inch Halligan bar and the 2 inch adze end of the bar. When forcing an outward swinging door it is advantageous to pry down on left side opening doors and pry up on right side opening doors. The key is to roll up in the direction opposite the pick to gain maximum leverage.

Forcing inward swinging doors is done in the same fashion as outward swinging doors except the Halligan is used in a different position yet the mechanical advantages will remain the same.

Using the adze end is similar to a class I lever. This is where the fulcrum placed between the effort and load. The movement of the load is in the opposite direction of the movement of the effort and the most typical lever configuration. Fulcrum or pivot point is the point on which an object balances or turns.

Using the Fork

When driving the fork between the door and the frame, the fork should be driven 3 inches past the edge of the door frame creating fulcrum. This will put our load on the Halligan at the 5 inch mark (the length of the crotch of the Halligan) at the door jamb, resulting in a load to fulcrum length of 2 inches. The more we drive our Halligan into the jamb the less we of a mechanical advantage we have when using the tool.

Using the fork is similar to a class II lever. This is where the load is between the effort and the fulcrum. In this, the movement of the load is in the same direction as the effort.

Work hard, stay safe and live inspired. 

About the Author

NICHOLAS J. HIGGINS is a firefighter with 14 years of service all within departments in Piscataway, NJ. Nick has held the ranks of Lieutenant and Captain as well as being a township elected District Fire Commissioner for 1 term (3 years) in Piscataway, NJ. He is also a NJ State certified level 2 fire instructor. He holds a B.S. in Accounting from Kean University working in Corporate Taxation and is the founder/contributor of the Firehouse Tribune website.